Yy0 - YY0 Linear transformer
Connection Diagram:
R | U | |
S | V | |
T | W | |
TN | WN | |
Connections(35) | Position | Remark |
WN | Right | |
W | Right | |
V | Right | |
U | Right | |
TN | Left | |
T | Left | |
S | Left | |
R | Left |
Parameters(5) | Default | Remark |
Vprimairy[RMS] | 10k | Primairy voltage [RMS] |
Power[VA] | 100k | Appearent power of the transformer [VA] |
Vsecundair[RMS] | 400 | Secundairy voltage [RMS] |
Frequency[Hz] | 50 | Frequency of the grid [Hz] |
uk[pu] | 0.06 | Short circuit voltage to be specified in pu, for example 6% is entered as 0.06 |
Function | Three phase YY0 transformer where the input and output voltage as well as KVA and short circuit voltag euk are specified. | |
Special | If uk is set to zero, also uk is approximated from the rated power and rated voltage. |
Status | Standard |
Select from | Components\Library\Transformers\ThreePhase |
See also
Dd0, Dd0y11, Dd0y5, Dd4, Dy11, Dy5, Yd11, Yd5, Ydy, Yy6,