HCFL - Hot Cathode Fluorescent Lamp

preview

Connection Diagram:

P1    P3
         
        
        
        
N1    N3

Connections(15)PositionRemark
P3 Top
P1 Top
N3 Bottom
N1 Bottom

Parameters(5)DefaultRemark
NegativeResistance[Ohm] -5 Negative voltage current Gas discharge relation
Vburn 100
Vignition 200
Rwire 1m
Lwire 1uH

Function The lamp ignites when the voltage accros the lamp is larger than Vignition. The lamp burns with an arc voltage equal to Vburn and a negative voltage current slope defiend by NegativeResistance
Special Be carefull with specifying Negative Resistance. Start with 1, run a simulatio and check the current and voltage waveforms. The Negative Resitance is limited to -Vburn/Iburn After checking the waveforms you can me Negative resistance gradually negative, to meet the HCFL specifications.

Status Standard