IMuvwxyzWR - Wound Rotor Induction Machine
Connection Diagram:
| SENSOR | SHAFT | ||
| US |
| UR | |
| VS | VR | ||
| WS | WR | ||
| XS | XR | ||
| YS | YR | ||
| ZS | ZR | ||
| M | |||
| Connections(15) | Position | Remark |
| ZS | Left | Stator Z connection |
| ZR | Right | Rotor Z connection |
| YS | Left | Stator Y connection |
| YR | Right | Rotor Y connection |
| XS | Left | Stator X connection |
| XR | Right | Rotor X connection |
| WS | Left | Stator W connection |
| WR | Right | Rotor W connection |
| VS | Left | Stator V connection |
| VR | Right | Rotor V connection |
| US | Left | Stator U connection |
| UR | Right | Rotor U connection |
| SHAFT | Top | Mechanical shaft of the induction machine |
| SENSOR | Top | |
| M | Bottom |
| Parameters(9) | Default | Remark |
| Lm | 19.4m | Stator Magnetizing Inductance |
| Lr=Lr'/N | 0.6m | Rotor leakage inductance in the rotor reference frame |
| Ls | 0.6m | Stator leakage inductance |
| p | 2 | pole pairs |
| J | 1m | Rotor Inertia |
| f | 1u | Friction of the rotor |
| Rr=Rr'/N | 44m | Rotor resistance in the rotor reference frame |
| Rs | 39m | Stator resistance |
| WindingRatio | 1 | Winding ratio between stator and rotor winding N=Nstator/Nrotor |
| Function | Induction machine model based on the stator fixed coordinate system. The rotor terminals are accessible on the right side of the machine. | |
| Special | Both the stator and rotor windings can used to create a wye or delta configuration. The rotor parameters are in the rotor reference frame | |
| Note | The rotor terminals always have to be connected to a three-phase circuit. | |
| Status | Standard | |
| Select from | Components\Library\ElectricalMachines\IM | |
See also
delta, IM, IMuvwxyz, IMwye, IMWYEwr, IMwye_Saturation, IMYD, IMYD_NamePlate, IM_DQSENSOR, IM_RotorSensor, IM_SquirrelCage, IM_StatorSensor, InductionMachineNamePlateParameters, Kloss, RotorResistance, WRIG, WRIG2,