IMuvwxyzWR - Wound Rotor Induction Machine
Connection Diagram:
SENSOR | SHAFT | ||
US | UR | ||
VS | VR | ||
WS | WR | ||
XS | XR | ||
YS | YR | ||
ZS | ZR | ||
M |
Connections(15) | Position | Remark |
ZS | Left | Stator Z connection |
ZR | Right | Rotor Z connection |
YS | Left | Stator Y connection |
YR | Right | Rotor Y connection |
XS | Left | Stator X connection |
XR | Right | Rotor X connection |
WS | Left | Stator W connection |
WR | Right | Rotor W connection |
VS | Left | Stator V connection |
VR | Right | Rotor V connection |
US | Left | Stator U connection |
UR | Right | Rotor U connection |
SHAFT | Top | Mechanical shaft of the induction machine |
SENSOR | Top | |
M | Bottom |
Parameters(9) | Default | Remark |
Lm | 19.4m | Stator Magnetizing Inductance |
Lr=Lr'/N | 0.6m | Rotor leakage inductance in the rotor reference frame |
Ls | 0.6m | Stator leakage inductance |
p | 2 | pole pairs |
J | 1m | Rotor Inertia |
f | 1u | Friction of the rotor |
Rr=Rr'/N | 44m | Rotor resistance in the rotor reference frame |
Rs | 39m | Stator resistance |
WindingRatio | 1 | Winding ratio between stator and rotor winding N=Nstator/Nrotor |
Function | Induction machine model based on the stator fixed coordinate system. The rotor terminals are accessible on the right side of the machine. | |
Special | Both the stator and rotor windings can used to create a wye or delta configuration. The rotor parameters are in the rotor reference frame | |
Note | The rotor terminals always have to be connected to a three-phase circuit. |
Status | Standard |
Select from | Components\Library\ElectricalMachines\IM |
See also
delta, IM, IMuvwxyz, IMwye, IMWYEwr, IMwye_Saturation, IMYD, IMYD_NamePlate, IM_DQSENSOR, IM_RotorSensor, IM_SquirrelCage, IM_StatorSensor, InductionMachineNamePlateParameters, Kloss, RotorResistance, WRIG, WRIG2,