Synchronous - RST to Ab transformation

preview

Connection Diagram:

            
L1 SHAFT
L2    
L3    
R1    
R2TORQUE
    X
AMILM

Connections(20)PositionRemark
X Right
TORQUE Right
SHAFT Right
R2 Left
R1 Left
LM Bottom
L3 Left
L2 Left
L1 Left
I Bottom
AM Bottom

Parameters(9)DefaultRemark
WindingRatio 1 Ratio between the number of stator and rotor windings N=Nstator/Nrotor
Rs 39m Stator resistance
Rr=Rr'/N^2 44m Rotor resistance in the rotor reference frame
f 1u Friction of the rotor
J 1m Rotor Inertia
p 2 pole pairs
Ls 0.6m Stator leakage inductance
Lr=Lr'/N^2 0.6m Rotor leakage inductance in the rotor reference frame
Lm 19.4m Stator Magnetizing Inductance

Function The input RST is transformed from three phase into the two phase alpha-beta system.
Va=2/3 ( Vr- Vs/2 - Vt/2 )
Vb=2/3 ( 1.7Vs/2 - 1.7Vt/2 )

Status Standard

Select from Components\Library\ElectricalMachines\Synchronous

See also
HydroGenerator, SynchronousGenerator, SynchronousMachine, SynReluctance, SynReluctance_MONITOR, TurboGenerator,