SynchronousMachine - Synchronous Generator

preview

Connection Diagram:

            
L1     
L2SHAFT
L3    
        
    TSENSOR
ZIF    
M        

Connections(15)PositionRemark
ZIF Left
TSENSOR Right
SHAFT Right
M Bottom
L3 Left
L2 Left
L1 Left

Parameters(9)DefaultRemark
WindingRatio 1 Ratio between the number of stator and rotor windings N=Nstator/Nrotor
Rs 39m Stator resistance
Rr=Rr'/N^2 44m Damping rotor resistance in the rotor reference frame
f 1u Friction of the rotor
J 1m Rotor Inertia
p 2 pole pairs
Ls_sigma 0.6m Stator leakage inductance
Ldamping=Ldamping'/N^2 0.6m Damper winding inductance referred to the rotor winding. The total inductance is defined by LM and is referred to the stator winding. Select the correct winding ratio to distinguish between stator and field inductance.
Lm 19.4m Stator Magnetizing Inductance

Function Synchronous machine model with field excitation and damper windings.
Special The stator windings are in wye configuration.

Status Standard

Select from Components\Library\ElectricalMachines\Synchronous

See also
HydroGenerator, Synchronous, SynchronousGenerator, SynReluctance, SynReluctance_MONITOR, TurboGenerator,
© 2024 CASPOC, All rights reserved. Home   |   Terms and Conditions   |   Legal   |   Export Compliance   |   Privacy Policy   |   Site Map