PFC - Limited PI controller K,tau
Connection Diagram:
L | DC | |||
N | M | |||
Connections(37) | Position | Remark |
N | Left | |
M | Right | |
L | Left | |
DC | Right |
Parameters(5) | Default | Remark |
PowerFactor[0..1] | 1 | Power Factor ranging from 0 to 1 |
Efficiency[0..100] | 95 | Efficiency of the total system |
Vdc[V] | 500 | DC voltage level, maintained by the power factor controller. |
InitialACVoltage[V] | 230 | Initial guess for the power factor controller, select either 230 or 120 volt. |
Q[VAR] | 0 | Reactive Power |
Function | PI controller where the integration I is limited between min and max Parameters are specified as the proportional gain K and time constant tau | |
Special | The limiter is inside the integrator I and therefore has anti-windup |
Status | Standard |
Select from | Components\Library\PowerConverters\System |
See also
ACDC1phase, ACDC3phase, ActiveFrontEnd, B6U, CurrentLimiter, CurrentLimiterBiDirectional, DC2AFE, DCAC3Phase, DCAC3PhaseGrid, DCAC3PhasePWM, DCAC3PhaseVectorControl, DCACSinglePhase50Hz, DCACSinglePhase60Hz, DCDC, DCDCControlledCurrentLimited, DCDC_Bidirectional, DCGridSinglePhase, DCGridThreePhase, DCGRIDTHREEPHASEHarmonics, GRIDCONNECTION, RotorSideConverter, RotorSideConverterPQ,