DirectVectorControlParameters - Direct Vector Control Parameters
Connection Diagram:
D_I | D_P | Q_I | Q_P | W_I | W_P | ZPI_MAX | ZPI_MIN | ||
Connections(8) | Position | Remark |
ZPI_MIN | Top | |
ZPI_MAX | Top | |
W_P | Top | |
W_I | Top | |
Q_P | Top | |
Q_I | Top | |
D_P | Top | |
D_I | Top |
Parameters(8) | Default | Remark |
KP_AngularSpeed | 100 | |
KI_AngularSpeed | 10 | |
KI_D | 1 | |
KP_D | 10 | |
KP_Q | 10 | |
KI_Q | 1 | |
Minimum | 0 | |
Maximum | 500 |
Function | Use this block to specify the parameters for the direct vector control block |
Status | Standard | |
Export of Embedded C Code | YES |
Select from | Components\Library\Control\FieldOrientedControl |
See also
CurrentControl, DirectVectorControl, HystereseCurrentControl, HystereseCurrentControlSinglePhase, IdIqWslip, K_Tau, PMSMRotorFluxObserver, PWM_CONVERTER, PWM_CONVERTER_Fs_A, VCO, w2a, w2a_AdvanceAngle,