Fault - Fault three phase, independent control

preview

Connection Diagram:

                                
U     
V    
W    
ABC                    

Connections(26)PositionRemark
W Left Electric connection
V Left Electric connection
U Left Electric connection
C Bottom Control input phase C
B Bottom Control input phase B
A Bottom Control input phase A

Parameters(4)DefaultRemark
Ron[Ohm] 10m Breaker on resistance in [Ohm]
Roff[Ohm] 1e6 Breaker off resistance in [Ohm]
Rfault 10 Fault resistance between the phases in [Ohm]
Rground 100k Ground resistance in [ohm]

Function The faults are controlled from the external control input c. Compared to the Breaker that breaks only during the next zero corossing of the current, the fault can be toggled at any time Each fault can be controlled seperately

Status Standard

Select from Components\Library\PowerSystems\Switch\ThreePhase