Fault - Fault three phase, independent control
Connection Diagram:
U | |||||||||
V | |||||||||
W | |||||||||
A | B | C |
Connections(26) | Position | Remark |
W | Left | Electric connection |
V | Left | Electric connection |
U | Left | Electric connection |
C | Bottom | Control input phase C |
B | Bottom | Control input phase B |
A | Bottom | Control input phase A |
Parameters(4) | Default | Remark |
Ron[Ohm] | 10m | Breaker on resistance in [Ohm] |
Roff[Ohm] | 1e6 | Breaker off resistance in [Ohm] |
Rfault | 10 | Fault resistance between the phases in [Ohm] |
Rground | 100k | Ground resistance in [ohm] |
Function | The faults are controlled from the external control input c. Compared to the Breaker that breaks only during the next zero corossing of the current, the fault can be toggled at any time Each fault can be controlled seperately |
Status | Standard |
Select from | Components\Library\PowerSystems\Switch\ThreePhase |
See also
Breaker, ChangeOver, Switch, SwitchSeperateControl,