VAWT - Vertical Axis Wind Turbine, VAWT

preview

Connection Diagram:

        
VW SHAFT
CPLAMBDA

Connections(4)PositionRemark
VW Left WindSpeed
SHAFT Right
LAMBDA Bottom
CP Bottom Turbine power constant 0.1 .. 0.5

Parameters(8)DefaultRemark
Cp_minimum 0.01 Minimum value of Cp
Cp_Maximum 0.59 Maximum value of Cp (Theoretical limit = 0.59)
A[m2] 10 Turbine swept area [m2]
Rho 1.2 Air Density
R[m] 1 Radius of the wind turbine [m]
Inertia[Kgm2] 10 Inertia of the rotor [Kg m^2]
Friction[Nms/Rad] 1 Friction of the rotor [Nm / (Rad/s) ]
InitialRotorSpeed[Rad/s] 0 Initial speed of the turbine [Rad/s]

Function Vertical axis wind turbine where the rotor radius and swept area can be defined independently

Status Standard

Select from Components\Library\GreenEnergy\Wind

See also
Cp1, CpHeier, DrawCp, MaximumTorque, MPPwindpower, OptimumPower, Wind, WindTurbine,