ManualMotorProtector -
Connection Diagram:
U | V | W | ||
X | Y | Z |
Connections(34) | Position | Remark |
Z | Bottom | Electric connection |
Y | Bottom | Electric connection |
X | Bottom | Electric connection |
W | Top | Electric connection |
V | Top | Electric connection |
U | Top | Electric connection |
Parameters(4) | Default | Remark |
Ron[Ohm] | 10m | Breaker on resistance in [Ohm] |
Tdelay[s] | 10 | Delay in seconds before the thermal breaker will trigger if I>Irated |
Imax | 100 | Maximum current in [A] If I > Imax, the magnetic breaker will trigger immediately |
Irated[A] | 10 | Rated current in [A] If I > Irated, the thermal breaker will trigger |
Function |
Status | Standard |
Select from | Components\Library\PowerSystems\Protection\ThreePhase |
See also
CB, CircuitBreaker, RCD, ResidualCurrentCircuitBreaker,