DCM

DC Machine
Inputs(5) Va Vf w La Lf
Parameters(7) La(0) Lf(0) Ra Rf K Ia(0) If(0)
Default La(0)=1, Lf(0)=1, Ra=1, Rf=1, K=1, Ia(0)=0, If(0)=0,
History block YES
Select from Components/Blocks/Machines
Function General DC machine model







Z
P
2a
Number of conductors of armature windings.
Number of pole pares.
Number of armature current paths.

Inputs
Va, Vf
wm
La, Lf
Armature and Stator field voltage.(V)
Armature angular speed. (Rad/s)
Variable Armature en Stator field inductance. (Henry) La and Lf can be changed to simulate saturation.

Parameters
La(f=0),
Lf(f=0)
Ra, Rf
K
ILa(0),
ILf(0)
Constant Armature field inductance. (H)
Constant Stator field inductance. (H)
Armature and Stator field resistance.(W)
EMF constant. (V)
Initial conditions for the armature current. (A)
Initial conditions for the stator current. (A)
Special The output of the block is electric torque
Connecting Va and Vf to a voltage block, connects the DC machine into the circuit file.
© 2024 CASPOC, All rights reserved. Home   |   Terms and Conditions   |   Legal   |   Export Compliance   |   Privacy Policy   |   Site Map