Parameters(17) | Default | Remark |
Lq[H] |
1m |
Stator quadrature axis inductance in [H] |
Ld[H] |
1m |
Stator direct axis inductance in [H] |
initialSpeed |
0 |
Initial angular speed of the rotor [Rad/s] |
frictionLinear[Nm/Rad/s] |
1u |
Bearing friction of the rotor and eddy current loss friction[Nm/Rad/s] |
frictionWindage[Nm/ (Rad/s)^2) ] |
0 |
Windage friction loss [Nm/ (Rad/s)^2) ] |
frictionCoulomb[Nm] |
10u |
Constant coulomb friction due to Hysteresis loss in the stator [Nm] |
V5[V/Rad/s] |
0 |
Fifth Harmonic back-emf constant [V/Rad/s] |
V3[V/Rad/s] |
0 |
Third Harmonic back-emf constant [V/Rad/s], not visible in wye connected PMSM without neutral connection |
initialPosition |
0 |
Initial position of the rotor [Rad] |
Rs[Ohm] |
10m |
Stator Series Resistance |
Ke[Vpeak/Rad/s]=[Nm/A]=[Wb] |
0.1 |
Flux induced in the stator windings (Wb) by the rotor permanent magnets |
PolePair[.] |
10 |
Number of pole pairs [#] |
inertia[Kgm2] |
1m |
Rotor Inertia in [Kgm2] |
V7[V/Rad/s] |
0 |
Seventh Harmonic back-emf constant [V/Rad/s] |
alpha_Rs[1/K] |
0.00393 |
Temperature coefficient of the winding resistance [1/Degrees Celsius] |
alpha_Br[1/K] |
-0.002 |
Temperature coeficient of the permanent magnet [1/Degrees Celsius] |
Ls(LeakageInductance) |
1u |
Stator leakage inductance [H] |