DCM -
Connection Diagram:
ZA1 | ||||||||||
SHAFT | ||||||||||
ZA4 | ||||||||||
ZC1 | ||||||||||
ZC4 | ||||||||||
Connections(60) | Position | Remark |
ZC4 | Left | |
ZC1 | Left | |
ZA4 | Left | Armature electrical connection 2 |
ZA1 | Left | Armature electrical connection 1 |
SHAFT | Right | Mechanical shaft |
Parameters(8) | Default | Remark |
VAnom[v] | 400 | Nominal armature voltage [Volt] |
VFnom[V] | 400 | Nominal field voltage [V] |
Efficiency[0..1] | 0.9 | Efficiency, defines both winding resistance and friction losses default set to 0.9 |
NstatorPoles | 4 | Number of Stator poles |
NrotorPoles | 4 | Number of Rotor Poles |
Pnom[Watt] | 2k | Nominal power in [Watt] |
Nnom[rpm] | 1400 | Nominal speed in [Rotatings per minute] |
IFnom | 1 | Nominal field current [A] |
Function |
Status | Standard |
Select from | Components\Library\Laboratory\ElectricMachines\DC |
See also
Compound, PMDC, Series, Shunt, Universal,