DCM -
Connection Diagram:
| ||||||||||
| ZA1 | ||||||||||
| SHAFT | ||||||||||
| ZA4 | ||||||||||
| ZC1 | ||||||||||
| ZC4 | ||||||||||
| Connections(60) | Position | Remark |
| ZC4 | Left | |
| ZC1 | Left | |
| ZA4 | Left | Armature electrical connection 2 |
| ZA1 | Left | Armature electrical connection 1 |
| SHAFT | Right | Mechanical shaft |
| Parameters(8) | Default | Remark |
| VAnom[v] | 400 | Nominal armature voltage [Volt] |
| VFnom[V] | 400 | Nominal field voltage [V] |
| Efficiency[0..1] | 0.9 | Efficiency, defines both winding resistance and friction losses default set to 0.9 |
| NstatorPoles | 4 | Number of Stator poles |
| NrotorPoles | 4 | Number of Rotor Poles |
| Pnom[Watt] | 2k | Nominal power in [Watt] |
| Nnom[rpm] | 1400 | Nominal speed in [Rotatings per minute] |
| IFnom | 1 | Nominal field current [A] |
| Function | ||
| Status | Standard | |
| Select from | Components\Library\Laboratory\ElectricMachines\DC | |
See also
Compound, PMDC, Series, Shunt, Universal,