ACAnimation - RST to Ab transformation
Connection Diagram:
| |||||||||||||
| L1A | |||||||||||||
| L2A | SHAFT | ||||||||||||
| L3A | |||||||||||||
| Connections(68) | Position | Remark |
| SHAFT | Right | |
| L3A | Left | |
| L2A | Left | |
| L1A | Left |
| Parameters(4) | Default | Remark |
| PolePair[.] | 1 | Number of pole pares |
| Ke[Vpeak/(Rad/s)]]=[Nm/A] | 1 | Torque / back emf constant in [Vpeak/Rad/s] or [Nm/A] |
| Ns | 48 | Number of stator poles |
| Nr | 8 | Number of rotor poles |
| Function | The input RST is transformed from three phase into the two phase alpha-beta system. Va=2/3 ( Vr- Vs/2 - Vt/2 ) Vb=2/3 ( 1.7Vs/2 - 1.7Vt/2 ) |
|
| Status | Standard | |
| Select from | Components\Library\ElectricalMachines\System | |
See also
AC, DC, Generator, VariableSpeedDrive, VariableSpeedDriveControlled, VariableSpeedDriveControlledDoublyShaft, VariableSpeedDriveDoublyShaft,