SinglePhase - Brushless DC Machine Single Phase

preview

Connection Diagram:

T
L1 SHAFT
        
        
L2    
M

Connections(7)PositionRemark
T Top
SHAFT Right
M Bottom Model parameters
L2 Left
L1 Left

Parameters(8)DefaultRemark
Friction[Nms/Rad] 1m Rotor friction [Nm / (Rad/s) ]
Inertia[]Kgm2] 1m Rotor Inertia [Kgm2]
StatorInductance[H] 10mH Stator winding inductance [Henry]
Rs[Ohm] 1 Stator winding resistance [Ohm]
InitialAngularSpeed[Rad/s] 0 Initial angular speed of the machine [Rad/s]
np 2 Number of pole pairs [.]
K 0.1 Torque / Back Emf Constant [Nm/A] or [Vs/Rad]
InitialAngularPosition[Rad] 0.753 Initial angular position of the rotor in Radians

Function The single phase machine has only one winding and one rotor magnet.
Special Depending on the initial angular speed or initial angular position, the machine rotates in either clockwise or anti-clockwise
Note Either the initial angular position or the initial angular speed have to be non-zero

Status Standard

Select from Components\Library\ElectricalMachines\Brushless

See also
BLDCM, BLDCMdelta, BLDCMwye, BLDCM_FEM, BLDCM_FEM_StarWye, Brushless, BrushlessDC, BrushlessDC_Monitor, BrushlessDC_NamePlateParameters, CommutationSequence120, EC, wye,
© 2024 CASPOC, All rights reserved. Home   |   Terms and Conditions   |   Legal   |   Export Compliance   |   Privacy Policy   |   Site Map