Nominal current | In | 21.93 | [Ampere] |
Nominal Torque | Tn | 3.185 | [Nm] |
Torque constant | Kt | 0.145 | [Nm/A] |
Back emf constant | Ke | 0.145 | [V/(Rad/s)] |
Electrical time constant | τe | 20 | [ms] |
Mechanical time constant | τm | 40 | [ms] |
Rotor inertia | J | 7.708 | [mKgm2] |
Stator winding resistance | Ra | 109.44 | [mΩ] |
Stator winding inductance | La | 2.189 | [mH] |
Back EMF | Vemf | 45.6 | [V] |
Vloss | VRa | 2.4 | [V] |
Ploss | PRa | 52.632 | [W] |
Pmechanic | Pm | 1000 | [W] |
Pelectric | Pe | 1052.632 | [W] |
Help
Enter the nominal power, voltage and angular speed and see the open loop response of this motor drive.
To change the winding resistance Ra, change the efficiency η of the motor
To change the motor constant Ke and Kt, change either the motor voltage Vn or the nominal speed ωn of the motor
4
5